Skip to main content

Table 3 The comparison of performances between parameters

From: Prediction of fluid responsiveness in mechanically ventilated patients in surgical intensive care unit by pleth variability index and inferior vena cava diameter

Parameters

CVP

PVI

dIVC

Threshold values

≥ 5 mmHg

> 14%

> 19.42%

Sensitivity (%)

70.83

93.75

79.17

Specificity (%)

47.50

87.50

80

AUC (95% CI)

0.612 (0.502–0.714)

0.955 (0.889–0.988)

0.886 (0.801–0.944)

LR+

1.35

7.50

3.96

LR−

0.61

0.071

0.26

PPV

61.82

90

82.61

NPV

57.58

92.12

76.19

P

0.0648

< 0.0001

< 0.0001

  1. AUC (95% CI) area under ROC curve (95% CI), CVP central venous pressure, dIVC caval index, LR likelihood ratio, NPV negative predictive value, PPV positive predictive value, PVI pleth variability index