Skip to main content

Table 2 Diagnostic performance of DE and DTF in some studies

From: Ultrasound-assessed diaphragmatic dysfunction as a predictor of weaning outcome in mechanically ventilated patients with sepsis in intensive care unit

Author/Year

Patient category

Measures

Best cut off value

Accuracy

Jiang et al., 2004

Medical ICU patients

DE

11 mm

Sensitivity 84.4%, specificity 82.6%

Kim et al., 2011

Medical ICU patients

DE

14 mm (right) and 12 mm (left)

Sensitivity of 60%, specificity of 76%, AUC = 0.68

DiNino et al., 2014

Mixed ICU patients

DTF

30%

Sensitivity of 88%, specificity of 71%, AUC = 0.79

Ferrari et al., 2014

MV patients received tracheostomy in high dependency unit

DTF

36%

Sensitivity of 82%, specificity of 88%

Ali and Mohamad, 2016

Mixed ICU patients

DE

15 mm

Sensitivity of 88.7%, specificity of 84.3%

DTF

30%

Sensitivity of 97.3%, specificity of 85.2%