Skip to main content

Table 2 Improvement in SpO2 and P/F ratio

From: Awake self-proning for COVID-19 non-intubated patients—a single-centered experience

Variable

Supine

Prone

p-value

SpO2 (%)

86 (76–90)

94 (89–97) (approximately 30 min after initiation of proning)

0.001

P/F ratio (mm of Hg)

90.7 ± 25.8

132.7 ± 42.6 (24 h after initiation of proning)

 < 0.0001

  1. Data presented as median, interquartile range, mean ± standard deviation